EM513082/83/84 are advanced bidirectional metering device with MID certification and Modbus and M-Bus communication protocol for recording AC power consumption and output of three-phase network, active energy, current, voltage, power, as well as many other parameters.The device for making indications in metric units (kWh), is used to directly measure active power in a three-phase system. A special electronic system under the influence of the flowing current and applied voltage generates pulses in an amount proportional to the electricity consumed. The energy consumption in the phase is indicated by the flashing of the LED. The number of pulses is converted into the energy consumed, and its value is indicated by the LCD display (6+2). Power supply: 230V~, 50Hz, base current: 5A, max. current: 100A, min. current: 0.25A, pulse frequency: 800 imp/kWh, accuracy class B, housing with a width of three modules, mounting on a DIN rail TH-35 mm, pulse output: power supply 12~27V, current 27mA, pulse = 80ms. The energy measurement is carried out in accordance with EN50470-1:2006, EN50470-3:2006 of the MID Directive 2014/32/EU.

EM519082 83 84 DIN-Rail mount modules Three-phase MID electricity meter 75A 80A 100A mid approved meter

1.Product Introduction

Looking for reliable and accurate three-phase energy metering? Our EM51308 series offers a powerful solution tailored to your needs. All models boast Class B accuracy, support bi-directional active and reactive energy measurement, and comply with EN50470-1/3 standards for dependable performance. Installation is a breeze with their standard DIN rail design.

  • EM513082: Featuring versatile RS485 communication (Modbus & DLT645 compatible), this model also includes a built-in battery for data security and integrated tariff functionality for advanced billing applications.

  • EM513083: Offering seamless integration with monitoring systems via RS485 (Modbus & DLT645 compatible), this meter provides robust and accurate energy data.

  • EM513084: Equipped with a standardized IR communication port (EN62056/IEC1107 protocol), this model allows for convenient local data access.


2.Common Features

  • Voltage and Current: All operate at 3x230/400V and support a current range of 5(100)A.

  • Accuracy Class: All three meters have a Class B accuracy rating.

  • Metering Functionality: All support bi-directional measurement of both active and reactive energy.

  • Standards Compliance: All models meet the requirements of EN50470-1/3.

  • Installation: All are designed for easy DIN rail mounting.

  • Meet with RE test, EMI compatible

  • MID Module B+D, newest standard


3.Differeces

The EM513083 and EM513082 both offer versatile RS485 communication with dual protocol support. However, the EM513082 distinguishes itself with the inclusion of a battery and tariff capabilities. The EM513084 utilizes an IR communication port based on the EN62056 standard and does not have battery or tariff features.

 

4. Technical Parameters

Model

EM513084

EM513083

EM513082

Pulse Constant

1000imp/kWh

1000imp/kvarh

1000imp/kWh

1000imp/kvarh

1000imp/kWh

1000imp/kvarh

Communication

IR

IR,RS485 Modbus/DLT645

IR,RS485 Modbus/DLT645

Baud Rate

N/A

9600\19200\

38400\115200

9600\19200\

38400\115200

SO Output

SO1 refers to the total active power (default) or active/reactive forward power (optional)

The pulse constant can be set and is divisible by 96000


SO2 refers to total reactive power (default) or active/reactive reverse power (optional)

The pulse constant can be set and is divisible by 96000

Backlight

Blue

Blue

Blue

Lithium Battery

N/A

N/A

YES

Multi-Tariff

N/A

N/A

YES

Measurement model

1.Total=Forward

2.Total=Reverse

3.Total=Forward +Reverse (Default)

4.Total=Forward-Reverse

Button

Touch Button

Button Function

Left button: Turn the page,

Right button: Turn the page and set the information display

Default setting

1000imp/kWh

1000imp/kvarh

1000imp/kWh

1000imp/kvarh

9600/NONE/8/1

1000imp/kWh

1000imp/kvarh

9600/NONE/8/1

Metering Mode Setting

Button

 RS485 or Button

RS485 or Button

 


5. Application

Totalization of the electric energy in the industry for every single line or machine in the factory area

Measurement of energy generated by renewable sources such as solar, eolic, etc. 

Suits for Mode 2/3/4/Inductive EV Charging 

Accounting and billing of consumptions in camp sites, malls, residential areas, naval ports, etc. 

Totalization of the electric consumption in hotels, congress centers, and exhibition fairs. 

Accounting of the consumptions in buildings with executive office services. 

Internal allocation of the consumptions in timeshare civilian and industrial buildings. 

Realization of energy monitoring systems. 

Remote survey of the consumptions and compute of the costs


6. Highlight

Meet with RE test and EMI

RS485-modbus and M-bus optional

MID certified